/ep_edm/en/contect_1290.html View of Shini
Language
English 繁體中文
2018-12-12
2018 Quarter 3 Issue 36
Related Articles
Diversify New Territory; Realize One-stop ShoppingShini Efforts on CFC-free RefrigerantsIntroduction of Basic Knowledge on RefrigerationSolution for Chilling Power Reducing of SIC-8W Water ChillersSolution for Temperature Difference of SIC-8W Water ChillersReport on the Establishment of Shini Water Chiller Performance LaboratoryPortable Water Chiller SIC-3A~12.5A-R2Interview with Shini Assistant General Manager Chris ChangCHINAPLAS 2010 Post-show ReportTrouble-shooting for SICC-W Central Water Chillers18th Düsseldorf K-show Ends Completely & Successfully2010 Seen Shini Brilliant AchievementsShini Received National Production License for Refrigeration EquipmentHow Thermal Expansion Valve Works in RefrigerationWater Chillers SIC-3W/AExclusive Interview with Steven ChenHow Hot-air Bypass Solenoid Valve Works in RefrigerationWhat is Shini Doing during RecessionHow Compressor Works in Refrigeration13th DMP Ends Completely & SuccessfullyWater-cooled Chillers SIC-14W-R2Air-cooled Water Chillers SIC-7.5A-R2Water-cooled Water Chiller SIC-56W-R2The Future is in Plastic and Rubber---CHINAPLAS2012Shini at DMP 2012Revolution of Industrial Water Chillers SICAir-cooled Water Chillers SIC-24A-R2Five Questions, to Explore the Road of Development of the Auxiliary Equipment Industry LeaderAir-cooled Chiller SIC-18A-R2Medical and Optical System SolutionThe Principle and Application of Industrial Air ChillerSolutions of Central Cooling SystemShini Water Chiller will Be Entirely UpgradedIndustrial Water Chiller COP Introduction & the China StandardTemperature Control for Water Chiller Outlet WaterReview 2015 and Look Forward to 2016Model Selection and Notices of Cooling TowerEnergy Saving Technology Applied in Water ChillerThe New Technology of Shini Water ChillerCase Sharing of Central Conveying SystemThe Significance of COP to Cooling SystemCase of Plant Solution for Doors and Windows Motor ProductsCFC-free Refrigerant Water-cooled Water Chiller SIC-17W-R2Application of Industrial 4.0 Smart PlantMagnetic Central Chiller
Special Reports
A  A  A
CFC-free Refrigerant Water-cooled Water Chiller SIC-17W-R2

Features

1.Cooling range 7~25oC/44.6oF~77oF.

2.Insulated water tank made of stainless steel.

3.Equipped with anti-freeze thermostat.

4.Adopt R410A refrigerant, used to improve coefficient of performance (COP) and R410A is ozone-friendly.

5.Refrigeration loop controlled by high and low pressure switches.

6.The compressor and pump both have overload protection.

7.Standard equipped with the hot-gas bypass valve, with the control accuracy reaching ±1oC/1.8oF.

8.All adopt quality compressors from major supplier.

9.Middle Pressure Pump is standard.  
10.Adopts tube-in-shell condenser design. Without any need of cooling water for excellent heat transfer and rapid cooling.

11.Equipped with RS485 communication interface to realize centralized monitoring.

12.The plate heat exchange is equipped with the stacked filter.

13.The stainless steel water pipe adopts PVC-U that is environmental friendly for long service life.

Options

1.High pressure pump are optional to meet any pressure requirements.

2.Water tank level sensor is available to detect whether the water level is normal.

3.Solenoid valve is optional to prevent compressor re-start and the liquid impact phenomenon by cutting the refrigerant immediately after downtime. 

4.Refrigerant indicator can be opted to detect the refrigerant and the water ratio.

5.Optional flow switches to ensure system works in sufficient water quantity.



Application

It is applied to plastics industry to precisely control moulds temperature so that molding cycle can be reduced and quality would be improved. Also SIC-W-R2 series can be applicable for electronic and machinery manufacturing to ensure normal operation temperature for devices.

FreeFree
For registered members onlyFor registered members only
For business partners onlyFor business partners only
Top